ATEx Infrared CO2 Carbon Dioxide C4 sensor with integrated digital & analogue 0.4-2.0V output, 0-5000ppm; 0-1%; 0-2%; 0-5%; 0-20%; 0-30% or 0-100% volume CO2
Product Code: 2112BC4A-VQuick Overview
ATEx certified infrared C4 Carbon Dioxide CO2 C4 sensor in 4 series standard size with integrated analogue 0.4-2.0Vdc transmitter, 0-5000ppm. Optional: 0-1%, 0-2%, 0-5%, 0-30% volume CO2
Add to enquiry
Details
ATEx certified infrared C4 Carbon Dioxide CO2 C4 sensor in 4 series standard size with integrated analogue 0.4-2.0Vdc transmitter. Output on request
Measuring Ranges: Standard: 0-5000ppm CO2. Optional: 0-1%vol.; 0-2% vol.; 0-5% vol.; 0-20% vol; 0-30% vol or 0-100% volume CO2
Sensor size: 4 series
Part no: 2112BC4A-V
- Integrated digital Modbus and analogue (voltage) standard output
- Incorporated signal linearisation and temperature compensation suited for manufacturers without any specialist knowledge in IR technology
- Standard sensor size 20mm (4 series)
- Fast response
- Robust construction
- Wide operating temperature and humidity range
- Low power consumption
- ATEx approved version
This high performance CO2 infrared sensor determines the level of infrared light absorbed when the target gas enters the sensor. The sensor features a long-life tungsten filament bulb and pyroelectric detector. Available in 4 series sensor size, this sensor also has the advantage of driver circuitry with ATEx approval.
The C4 series of infrared gas detection sensors utilise NDIR (Non Dispersive Infrared) to monitor the presence of Carbon Dioxide CO2, on which the sensor is precalibrated.
This technique is based on the fact that the gas has an unique and well defined light absorption curve in the infrared spectrum that can be used to identify the specific gas. The gas concentration can be determined by using a suitable infrared source and analysing the optical absorption of the light that passes through the gas.
The sensor contains optics and incorporated electronics with software in order to provide an output that is linearised and temperature compensated. The type of output is digital Modbus procol and analogue voltage type, 0.4-2Vdc (other voltages are available on request).
The sensor provides a linearised and temperature compensated analogue voltage output that is proportional to the gas concentration. This version is ATEx certified.
Available options:
– Standard version infrared CO2 sensor in 4 or 7 series sizes with integrated analogue (standard 0.4-2.0V) transmitter. Output on request (part no. 2112BC4-V)
– Installation kit and test gas cap.